How do I interpret my electronic pumps blinking?

Created by Matteo Franceschini, Modified on Mon, 11 Dec, 2023 at 2:36 PM by Matteo Franceschini

 If you're trying to understand what your pump is telling you, this is the right place!


LED COLORSSOLIDBLINKING SLOWBLINKING FASTOTHER
(500ms)(150 ms)
GREENTarget pressure precisely reachedReady
 to start
--
YELLOWTarget pressure not reached-Automatic recalibration performed-
REDShortcircuit or hard overcurrent detected multiple timesShortcircuit or hard overcurrent detected onceUnexpectedly high currents detected-
BLUELiquid is present-Priming mode
RED +BLUE
 ALTERNATING
-Liquid has not been detected, pump stopped for protection--
RED SOLID +
 BLUE BLINKING
---Slow speed timeout reached or the connection with the control panel has been lost, after being detected
YELLOW+BLUE-Problems with the power supply--